February 20, 2018
 Home

 Contact Information

 Company Information

 Equipment For Sale

 Equipment Wanted

 600c w/120MMLC ASi-500 PV

 
 Equipment For Sale

Next Page

Linear Accelerator For Sale
VARIAN, 2100C - 2001
Description: 2001 Varian 2100C

o 6 & 15 MV photons o 6 - 20 MeV electrons
o MLC: 120-Leaf Millennium
o Software Revision 10.1
o Theraview Portal Imager
o Exact Couch
o Approx. 1,400 Beam Hours
o Approx. 50,000 filament hours
o Available Summer, 2018
CONTACT SELLER FOR PHOTOS & ATTRACTIVE PRICE
FINANCING AVAILABLE
Posted: February 19, 2018Updated: February 19, 2018
Contact us about this Listing No Image

Linear Accelerator For Sale
VARIAN, Clinac 21 EX 2004
Description: 2004 Varian 21EX

o 6 &18 MV
o 6-20 MeV
o MLC: 120-Leaf Millennium o New gun & Target 2016
o Beam Hours <2200
o Filament Hours <49000
o Partial spare parts kit
o PV = IS2A - ASi-500 with Exact Arm
o Available now

O Write for photos and full details
O AVAILABLE AT A VERY REASONABLE COST
O FINANCING AVAILABLE
Posted: February 19, 2018Updated: February 19, 2018
Contact us about this Listing No Image

Linear Accelerator For Sale
VARIAN, Clinac 21EX - 2001
Description: 2001 Varian 21EX

o 6 & 15 MV
o 6-18 MeV
o Software revision 11.1
o MLC: 120-Leaf Millennium
o ASi-1000 Portal vision with Exact arm (added 2008)
o Full portal dosimetry
o Spare parts kit
o Available now

CONTACT FOR PHOTOS & FULL DETAILS
ATTRACTIVE PRICE
FINANCING AVAILABLE
Posted: February 19, 2018Updated: February 19, 2018
Contact us about this Listing No Image

Linear Accelerator For Sale
VARIAN, Clinac 21EX - 2002
Description: 2002 Varian 21EX:

Photon Energies: 18 MV, 6 MV
Electron Energies: 6, 9, 12, 16, 20MeV
IMRT: Added 2003
Software Version: 6.3
Record & verify software unit is set up for?: Aria (not included)
Portal Imaging-date added: 2005
What type of Arm on PI (R or Exact)? EXACT
What type of cassette): IDU-20
When will equipment be available?: Spring 2018
Unit is Installed & Operational -Being used clinically
Was Klystron ever replaced?: No
Thyratron Replaced?: October 2016
Base frame is NOT available for removal
Baseframe Type: VEO
Type of Couch?: EXACT
Multi-leaf Collimator: 120 leaf
MLC Millenium or standard?: Millenium
Spare parts kit?: Yes
Filament hours: approx. 45000
Beam hours: approx. 2700
Includes all Wedges
Service Support: In House
Clear removal path
Additional fans have been added to cool Gun Deck to avoid GFIL Fault

CONTACT SELLER FOR FULL DETAILS, PHOTOS, and ATTRACTIVE PRICING
FINANCING AVAILABLE
Posted: January 05, 2018Updated: February 19, 2018
Contact us about this Listing No Image

Stereotactic Radiotherapy For Sale
ACCURAY, CyberKnife G4 Robotic - 2006
Description: 2006 CyberKnife G4 - 800 MU

o DOM:  mid-2006
o Model: G4 - 800 MU
o Couch Model: Standard

ROBOT:
o Robot Gen - G4
o Robot Model: Kuka 240
o Room Configuration: Normal

IMAGING SYSTEM:
o Detector Type: AN3
o Generators: Air Cooled XRS

PDU:
o PDU Model: Teal
o CK Software Revision: 9.5

MULTIPLAN:
o Multiplan QTY: 1
o Multiplan Version: 4.5
o MD Suite: Yes
o Storage Vault: No

OPTIONS ENABLED:
o 4D Planning: Yes
o X-Sight Lung Tracking: Yes
o Monte Carlo Dose Calculation: Yes 
o Sequential Optimization: Yes
o IRIS: Yes-IRIS 2
o Quick Review/Multiple Session: Yes

LINAC:
o Linac Dose Rate: 800 MU SHL

OPTIONS ENABLED:
o Lung Optimization Treatment: Yes 
o Xchange Table: Yes B
o IRIS Collimator: IRIS 2
o Fiducial Tracking: Yes
o Skull Tracking: Yes
o Synchrony: Yes
o Xsight Lung: Yes
o Xsight Spine: Yes

OPTIONS ENABLED:
o TmtReview: Yes



CONTACT SELLER ASAP FOR ADDITIONAL DETAILS AND PHOTOS or to arrange inspection and test of unit-Deinstallation planned in near term
FINANCING AVAILABLE
Posted: December 29, 2017Updated: February 19, 2018
Contact us about this Listing No Image

Stereotactic Radiotherapy For Sale
ACCURAY, CyberKnife G4 Robotic-1000 MU UPGRADE - 2007
Description: 2007 CyberKnife G4 - 1000 MU Upgrade:

o DOM:  9/31/2007
o Model: G4 - 1000 MU
o Couch Model: Standard

ROBOT:
o Robot Gen - G4
o Robot Model: Kuka 240
o Room Configuration: Normal

IMAGING SYSTEM:
o Detector Type: AN3
o Generators: Air Cooled XRS

PDU:
o PDU Model: Teal
o CK Software Revision: 9.5

MULTIPLAN:
o Multiplan QTY: 1
o Multiplan Version: 4.5
o MD Suite: No
o Storage Vault: Yes

OPTIONS ENABLED:
o 4D Planning: No
o X-Sight Lung Tracking: Yes
o Monte Carlo Dose Calculation 
o Sequential Optimization: Yes
o IRIS 1 or IRIS 2: IRIS 2
o Quick Review/Multiple Session: Yes

LINAC:
o Linac Dose Rate: 1000 MU SHL

OPTIONS ENABLED:
o Spine Prone Treatment: No
o Lung Optimization Treatment 
o In Tempo: No
o Xchange Table: Yes B
o IRIS Collimator: IRIS 2
o Fiducial Tracking: Yes
o Skull Tracking: Yes
o Synchrony: Yes
o Xsight Lung: Yes
o Xsight Spine: Yes

OPTIONS ENABLED:
o Plan Touch: No
o Reports: No
o TmtReview: Yes
o Brain AutoSegmentation: Yes
o Male Pelvis AutoSegmentation: Yes
o Remote Access: Yes
o Quick Plan: No

CONTACT SELLER ASAP FOR ADDITIONAL DETAILS AND PHOTOS -Deinstallation planned very soon Head : 1000 MU
Posted: December 28, 2017Updated: February 19, 2018
Contact us about this Listing No Image

Next Page